Index

Energy storageRebuild shelfTest and identify

Sealed lead-acid battery

Also called VRLA, 12 V 7 Ah, UPS battery.

The 12 V 7 Ah or 9 Ah block inside a small UPS, or a larger one in a bigger UPS. Very often the UPS was thrown out because this battery is already dead. Lead and acid, even when 'sealed'.

If you are new to this category

Batteries store energy. The useful ones in modern scrap are lithium cells, and they are also the ones that burn if they are crushed, overcharged, or wired together carelessly. A pack is usually thrown out because one cell in the chain is weak, not because every cell is dead. Swollen means stop.

Tape over bare metal ends as soon as a cell is loose. Charge only with a charger made for that chemistry and that number of cells in series.

A loose lithium cell
− flat+ buttonFull 4.20 V · name 3.6 V · stop near 2.5 V

The flat end is negative, the button end is positive. Nominal voltage is about 3.6 to 3.7 volts. Full, for an ordinary cell, is 4.20 volts. Below about 2.5 volts for a long time, or any swelling, means it is for recycling, not for a project. Tape the ends so a bunch of them cannot short in a drawer.

Specification. The right-hand column is what is typical. The label on the part in your hand wins if they disagree.
What to look forUsual figure
Voltage12 V nominal, about 13.6–13.8 float, about 14.4 cyclic. A resting voltage under 12.0 V is a tired battery; under 10.5 V it is probably sulfated.
CurrentThey can deliver a lot for a short time. Fuse the output.

Volts are electrical pressure, amps are how much current is flowing, and ohms are how hard the part resists that flow. A higher voltage than the part was built for is how salvage parts die on the bench. If a cell in the table says “read the stamp”, that stamp is the whole specification.

What people actually use it for

  • A float-charged backup
  • A 12 V source that is not lithium, if it still holds charge

Leave this one when

The case is swollen or cracked. Recycle it. Do not open the vents.

Buying a new one is the better idea when

A new SLA of the same size. The charger in the UPS may still be worth keeping even when the battery is not.

How to tell if this one still works

Resting voltage, then a known load for a known time. A battery that sags to 10 V as soon as you connect a modest lamp will not run an inverter.

Tools you will want: Meter, A lamp as a load.

Words on this page

Short meanings, so the rest of the entry is readable if you are not already doing this every weekend.

nominal
The nameplate voltage, not the exact voltage at every moment. A '12 V' lead-acid battery sits around 12.6 V when full and sags under load.

Where people actually find it

1 notes, most useful first. “Leave it” means the part is in that machine and you should not take it: it is dangerous, worn out, or only useful if you already know that exact repair.

Harvest at a glance
FromCallHow manyHow oftenWhere it sits
Uninterruptible power supplyWorth it1–2alwaysThe tray.
  • Worth pullingUninterruptible power supply1–2 · always
    In this particular machine
    12 V, often 7 or 9 Ah. Frequently sulfated.
    Where to look
    The tray.
    How to get it out
    Load-test. Recycle if it sags immediately.
    The condition to expect
    Often the reason the unit was scrapped.