Signal and hookup wire
Also called ethernet pairs, hookup wire, magnet wire, ribbon.
Copper with ordinary insulation, harvested from ethernet, telephone, USB, and the low-voltage harness of a dead machine. Ethernet is the best of them: twisted, plenty of it, decent copper.
If you are new to this category
Wire and plugs are how power and signals move. The insulation is the safety, not the copper. Ethernet cable is fine for small signals and low voltage. It is not a substitute for a power cord. A connector you can unplug is worth more than a wire you have to solder every time.
Match the plug that came with the brick. Center-positive is common and not universal. The drawing on the label is a map: the dot is the center, the ring is the outside.
The drawing on the brick is the polarity. A dot inside a C-shaped ring means the center is positive when the plus sign points at the dot. Measure anyway. The two common hole sizes, 2.1 mm and 2.5 mm, almost fit each other and that is how the center pin gets bent.
| What to look for | Usual figure |
|---|---|
| Ethernet | Often 24 AWG solid in the wall, stranded in patch leads. Four color pairs. Solid hates repeated flexing. |
| Magnet wire | From a dead motor or a transformer you are not keeping. The enamel is the insulation. Scrape it or it will not solder. It is not mains hookup. |
| Limits | Low voltage only, unless the insulation was originally mains-rated. When in doubt it is not. |
Volts are electrical pressure, amps are how much current is flowing, and ohms are how hard the part resists that flow. A higher voltage than the part was built for is how salvage parts die on the bench. If a cell in the table says “read the stamp”, that stamp is the whole specification.
What people actually use it for
- Signal wiring
- Low-voltage power at the current the gauge allows
- Twisted pairs for anything noisy
Leave this one when
The insulation is cracked. Old PVC does this and then shorts in the bundle.
Buying a new one is the better idea when
A spool of silicone hookup wire for anything you will flex. Salvage ethernet is for fixed wiring.
How to tell if this one still works
Continuity, then a nick inspection.
Tools you will want: Cutters, Iron.
Words on this page
Short meanings, so the rest of the entry is readable if you are not already doing this every weekend.
- mains
- Ordinary household wall power. It can kill. Unplug before you open anything that used it, and do not experiment on live wiring.
- transformer
- Two coils on an iron core. It changes voltage and, in a proper one, isolates the output from the wall. Heavy old adapters are this. Microwave oven transformers are a different, dangerous kind.
- continuity
- A meter mode that beeps when two points are connected. It is how you map a switch: beep, then click, then see if the beep changes.
Where people actually find it
5 notes, most useful first. “Leave it” means the part is in that machine and you should not take it: it is dangerous, worn out, or only useful if you already know that exact repair.
| From | Call | How many | How often | Where it sits |
|---|---|---|---|---|
| Desktop PC | Worth it | a harness | always | Supply cables. |
| Headphones | Bonus | 1 | always | The cable. |
| Fluorescent fixture | Bonus | a run | usually | The leads. |
| Seasonal light string | Bonus | metres | always | Between lamps. |
| CRT television or monitor | Leave it | the yoke | always | Around the neck. |
- In this particular machine
- Color-coded 12 V, 5 V, and ground, already terminated.
- Where to look
- Supply cables.
- How to get it out
- Cut the connectors you will reuse and label them.
- The condition to expect
- Insulation is usually still good.
- In this particular machine
- Fine enameled strands. A repair nightmare, a decent short lead if it still beeps.
- Where to look
- The cable.
- How to get it out
- Test each conductor.
- The condition to expect
- One conductor open is the usual fault.
- In this particular machine
- Mains-rated, if it was mains-rated.
- Where to look
- The leads.
- How to get it out
- Do not downgrade it into a mystery bin.
- The condition to expect
- Good.
- In this particular machine
- Thin, often 28 AWG or finer.
- Where to look
- Between lamps.
- How to get it out
- Fine for signals. Not for current.
- The condition to expect
- Insulation cracks on old sets.
- In this particular machine
- A deflection yoke. It is not a benign coil to unscrew for copper.
- Where to look
- Around the neck.
- How to get it out
- Leave it.
- The condition to expect
- Leave it.