Axial fan
Also called PC fan, muffin fan, case fan.
A framed fan that already solves mounting. PC fans are the standard. The dead ones are dead because of the bearing, which you cannot economically rebuild.
If you are new to this category
These parts spin, push, or pump. A motor is a machine that turns electricity into turning. Some start turning as soon as you connect a battery. Others look identical and will not move until a small circuit tells them which coil to power next. The label, or the number of wires, is how you tell them apart.
Count the thick wires before you apply power. Two wires usually mean a brushed motor that can run from a battery. Three thick wires usually mean a brushless motor. Keep the board that came with a brushless motor.
Two wires means power only, usually 12 volts on the label. Three wires means the third wire reports speed, often two pulses per turn. Four wires means the fourth wire is a speed command. Use the voltage on the label. A server fan is louder and draws more current than a desk fan of the same size.
| What to look for | Usual figure |
|---|---|
| Sizes | 40, 60, 80, 92, 120, 140 mm square are the PC standards |
| Voltage | 5, 12, or 24 V on the label. A 12 V fan often starts around 6–7 V. |
| Wires | 2 = power. 3 = tach (open collector, two pulses per rev typical). 4 = PWM on the fourth wire, usually 25 kHz, 5 V. |
| Current | A quiet 120 mm is about 0.1–0.3 A. A server fan is not quiet and is not 0.1 A. |
Volts are electrical pressure, amps are how much current is flowing, and ohms are how hard the part resists that flow. A higher voltage than the part was built for is how salvage parts die on the bench. If a cell in the table says “read the stamp”, that stamp is the whole specification.
What people actually use it for
- Enclosure cooling
- Solder-fume fan
- The tach wire as a crude speed sensor
Leave this one when
It howls, wobbles, or was packed with dust that has worn the sleeve. Harvest a fan from a machine that died of something else.
Buying a new one is the better idea when
If you need a known CFM and a quiet bearing. Salvage fans are a lottery you can hear.
How to tell if this one still works
Rated voltage. Listen. Feel for vibration. A pulse on the tach wire while it spins means the sensor works.
Tools you will want: Meter, 12 V source.
Words on this page
Short meanings, so the rest of the entry is readable if you are not already doing this every weekend.
- PWM
- A rapid on-off signal used to control speed or brightness. A four-wire computer fan uses it on the fourth wire.
Where people actually find it
7 notes, most useful first. “Leave it” means the part is in that machine and you should not take it: it is dangerous, worn out, or only useful if you already know that exact repair.
| From | Call | How many | How often | Where it sits |
|---|---|---|---|---|
| Desktop PC | Prize | 1–4 | usually | Front, rear, and on the CPU or supply. |
| Laser printer | Worth it | 1–2 | usually | Rear exhaust. |
| Ultrasonic humidifier | Worth it | 1 | usually | The top. |
| Space heater | Worth it | 1 | usually | Behind the element. |
| Uninterruptible power supply | Worth it | 1 | usually | Rear. |
| Desk or box fan | Bonus | 1 | sometimes | DC-powered modern fans. |
| Treadmill | Bonus | 1 | sometimes | Controller cooling. |
- In this particular machine
- 12 V, 80–140 mm. 3-pin or 4-pin.
- Where to look
- Front, rear, and on the CPU or supply.
- How to get it out
- Unplug. Do not salvage a screaming one; the bearing is the failure.
- The condition to expect
- Good if the machine was quiet.
- In this particular machine
- 12 or 24 V. The label decides.
- Where to look
- Rear exhaust.
- How to get it out
- Unplug.
- The condition to expect
- Good if it is not packed with toner dust.
- In this particular machine
- Small DC fan.
- Where to look
- The top.
- How to get it out
- Unplug.
- The condition to expect
- Good.
- In this particular machine
- Often a shaded-pole, sometimes DC.
- Where to look
- Behind the element.
- How to get it out
- If it is seized, that is why the fuse opened.
- The condition to expect
- Seized is common.
- In this particular machine
- 12 V.
- Where to look
- Rear.
- How to get it out
- Unplug.
- The condition to expect
- Good.
- In this particular machine
- The blade is on a BLDC and a small board.
- Where to look
- DC-powered modern fans.
- How to get it out
- The brick is the other half.
- The condition to expect
- Good.
- In this particular machine
- Mains or DC.
- Where to look
- Controller cooling.
- How to get it out
- Read it.
- The condition to expect
- Good.